MIDEA12HRFN8 BREZELESS INVERTER AC 1.0 TON


Room freeze protection, “Temperature maintenance function +8°C”: The air conditioning control system can maintain the room temperature at +8°C, so that the walls do not get too cold and the water supply does not freeze.

147,000

Compare

Cleaning

Cleaning

Active Clean technology washes away dust, mold and grease that can cause odor as they adhere to the heat exchanger, automatically freezing and then quickly defrosting the frost, warming up the heat exchanger. After that, the impeller continues to work in order to dry out the heat exchanger completely.
When this function is enabled, “CL” is displayed on the display of the indoor unit, after 20–45 minutes, the unit will automatically turn off and itself will cancel the active cleaning function.
To carry out cleaning in the future, you must re-enable this function.

Sine-Wave Inverter

Sine-Wave Inverter

Technology 180° -gradusnogo wave inverter conversion – control voltage without the “pulse” effects (jagged sinusoid).

Compared with the current standard of 120° rectangular wave has the following advantages:

  1. Ability to work with a wider range of supply voltage and frequency.
  2. Most of the energy efficiency and energy conservation.
  3. More soft start, lower noise and vibration.
  4. more control.

Aluminium heat exchanger with hydrophilic coating

Aluminium heat exchanger with hydrophilic coating

Improved wettability of the heat exchanger aluminum plates which have a special coating with a hydrophilic layer, ensuring rapid removal of condensate from the indoor unit that does not allow to quickly form of mold and bacteria, providing a more efficient operation of the air conditioner.

Refrigerant Leakage Detect

Refrigerant Leakage Detect

Its a electronical function of Main PCB and self-diagnostic system into AC.

When pipe-temperature sensor at inlet line of evaporator will indicate highest temperature, system will indicate “EC” code in a display of indoor units, its mean “ask for service centre for visit maintance team with leakage detectors and tools”

Energy efficiency А+++

Energy efficiency А+++

Energy efficiency is the effective (rational) use of energy resources. Use less energy to provide the same level of energy supply to buildings or manufacturing processes.

Outdoor unit design “Brilliant”

Outdoor unit design "Brilliant"

Designers Midea did not forget about the exterior of the exterior unit of the air conditioner, which in itself is a rarity for climate technology. The outdoor unit is much more elegant than its counterparts, it has facets like a diamond, and attention to detail speaks of a high level of production and a carefully thought-out design concept.

Compresor DC inverter

Compresor DC inverter

Compressor with inverter DC can increase the efficiency of the air conditioner, thus reducing power consumption saves your costs. This system is much more economical and safer than air conditioners with a constant output of the compressor.

Wi-Fi Control (Wi-Fi stick)

Wi-Fi Control (Wi-Fi stick)

Mission’s Wi-Fi and Smart Kits* are designed for even more comfortable and easy operation (for some series of Wi-Fi stick – option).

Customers can download absolutely free app for your smartphone with the QR-code located in the user’s manual.

 

Motor DC inverter indoor unit

Motor DC inverter indoor unit

The indoor unit is used to rotate the impeller DC – motor. This can significantly reduce noise and power consumption. And also get 12 positions change the speed of the impeller.

DC inverter motor Outdoor Unit

DC inverter motor Outdoor Unit

In outdoor units, a DC motor is used to rotate the fan. This allows you to significantly reduce noise and power consumption. And also get several positions of the fan speed, depending on the needs of the system.

Night Mode

Night Mode

Mode is activated with the remote control and provides a comfortable environment for a peaceful and deep sleep during the 7-hour cycle with a temperature change of reference values​​, as well as setting the minimum noise level and economical energy consumption. After that, the temperature returns to the originally specified value.

Ozone-friendly freon R32

Ozone-friendly freon R32

The new refrigerant R32 (difluoromethane) has significant advantages. First of all, it concerns the potential of global warming (GWP). If we compare the highly popular R410A refrigerant with R32, the latter differs by more than 65% of the GWP reduced. It follows that the environment is less affected by the new refrigerant. Also, R32 is characterized by reduced viscosity and density. Due to the lower density, the freon consumption is reduced, taking into account the same power figures. The density of difluoromethane is almost 30% less than that of R410A.

Crankcase Heater

Crankcase Heater

To prevent the compressor’s hydraulic impact, when the split system is in operation, in the cold season (at negative outdoor temperatures), an electric TEN is installed. The heating element is turned on when the compressor is stopped and does not allow condensed liquid freon in the oil in the compressor crankcase.

The heater of the outdoor unit pallet

The heater of the outdoor unit pallet

The heater of the outdoor unit pallet is installed to ensure complete removal of water from the heat exchanger of the outdoor unit resulting from defrost during the defrosting operation.

Maintaining temperature +8°С

Maintaining temperature +8°С

Protection against freezing of the room, maintaining the temperature of +8°C.

The control system of air conditioners can keep the room air temperature +8°C, so as not to cool the walls and freeze the water pipe. It is actual to use for summer residences, garages or if you leave on leave in the winter, and the constant warming up of a premise to a comfortable temperature is not required. At the same time, the air conditioner consumes less electricity, because the temperature difference between the street / room is also reduced.

Dry Mode

Dry Mode

Dry mode automatically selects cooling, based on the difference between fixed and temparaturoy actual room temperature. The temperature is regulated while reducing humidity repeated switching on and off of the cooling and ventilation only. when the dry mode on the remote control shows “Drop”

Follow Me

Follow Me

“Follow Me” feature

When this function is enabled on the remote control, the control unit of the indoor unit will receive data about the temperature in the room from the temperature sensor installed in the remote control, which allows you to more precisely control the operation of the air conditioner, reaching the set mode in the area where the remote control is in the room. The range of the signal from the console does not exceed 8 m. in a straight line “remote – indoor unit”.

Multi-Bend Heat Exchanger

Multi-Bend Heat Exchanger

Increased heat. This unit uses the heat exchangers with tubes of a special design, the inner surface of which has trapezoidal notches “Innergrove cooper”, which provides maximum heat transfer surface area increased. Due to this heat increases by 28%, reduced power consumption, and hence increases the efficiency of the system.

Full-DC (3D DC-inverter)

Full-DC (3D DC-inverter)

All engines compressors and fans in the system are made by DC-inverter technology.

Turbo

Turbo

Tthe «Turbo» function – when you turn on this mode, air conditioning provides the most rapid cooling or heating, to create comfortable conditions in the shortest possible time.

Low Ambient Cooling

Low Ambient Cooling

Low-temperature (season) set – used for the operation of the air conditioner in cooling mode at low ambient temperatures (usually provided in the air conditioner as an optional feature). The kit includes: the controller of the outdoor unit fan motor, compressor crankcase heater and heater drain line.

In some series of inverter split systems this option is implemented in hardware and software, thus if there is a need to use the air conditioner in the winter for cooling, you must install only drain the heater.

The Indoor Unit

Model Name
MSAG-18HRFN8-I
Power Options, V/Hz/Ph
220/50/1

Power, kW

Cooling Power
3.390
 5.900
Heating Capacity
3.100
 5.850

Power consumption, kW

Cooling
0.560
 2.050
Heating
0.780
 2.000

Energy Efficiency Class

Cooling
A++
Heating
при +2°С=A+++, при -7°C=A+

Energy Efficiency Ratio

SEER (cooling mode)
7.00
SCOP (heating mode)
4.00
 5.10
EER (сooling mode)
3.40
COP (heating mode)
3.71
Air flow rate, m³/h
800
 560
Noise level, dB
41.00
 20.00
Sound Power Level, dB(A)
54.00

Dimensions(WxHxD), mm

Without Package
969
x 241
x 320
in Multiples
1045
x 315
x 405

Weight, kg

Net Weight
11.20
Gross Weight
14.60

The outdoor Unit

Model Name
MSAG-18HRFN8-O
Compressors Type
Inverter
Compressor
GMCC ROTARY DC

Freon

Freon Type
R32
Freon Weight, kg
1.10, kg
Power Options, V/Hz/Ph
220/50/1
Air flow rate, m3/h
2,100
Noise level, dB
57.00
Sound Power Level, dB(A)
63.00

Diameter Pipes, mm

Liquid
6.35
Gas
12.70
Min length of main line, m
3
Max length of main line, m
30
Max vertical drop, m
20

Dimensions(WxHxD), mm

Without Package
874
x 554
x 330
in Multiples
915
x 615
x 370

Weight, kg

Net Weight
33.50
Gross Weight
36.10
×